Tuesday, February 07, 2012
|
|
DESICCANT DRYER- HDT
HDT absorption dryers are assembled in Havayar factory under Italian Friul Air license & Technology, using Friul Air spare parts.
TECHNICAL SPECIFICATION TABLE
Inlet air temperature 35' C
Pressure 7barg
Maximum working condition will be:
Maximum inlet air temperature: 50' C
Maximum ambient temperature: 50' C
Maximum inlet air pressure: 13barg
Design pressure: 16barg
Average required air for regeneration 12% (in stable operation)
Standard feeding source: 1Ph/230V-240V/50hz-60Hz
NOTICE: Please specify dew Point Pressure at order time
Correction Factor for Operating Pressure Changes |
16.0 |
15.0 |
14.0 |
13.0 |
12.0 |
11.0 |
10.0 |
9.0 |
8.0 |
7.0 |
6.0 |
5.0 |
4.0 |
INLET PRESSURE Barg |
1.56 |
1.52 |
1.47 |
1.42 |
1.37 |
1.31 |
1.24 |
1.17 |
1.09 |
1.00 |
0.90 |
0.77 |
0.62 |
Correction Factor |
Correction Factor for Intel Air Temperature Change |
50 |
45 |
40 |
35 |
30 |
25 |
TEMPRATURE (C) |
0.78 |
0.86 |
0.93 |
1.00 |
1.06 |
1.12 |
Correction Factor |
AIR QUALITY BASED ON ISO 8573.1
The outlet Compressed Air from HDT Dryers has the highest level of international standard.
Operation Condition & Frequency |
Extant Humidity in
7barg pressure |
Impacted
Dew Point(C) |
Quality Class |
(mg/m3) |
(ppmw) |
2 + 2 min Fix |
0.348 |
0.27 |
-70 |
1 |
5 +5 min Fix or DPD |
14.88 |
11.7 |
-40 |
2 |
7.5 + 7.5 min Fix or DPD |
110.25 |
86.5 |
-20 |
3 |
TECHNICAL SPESIFICATIONS OF DRYER TOWER
- Carbon steel made Towers with powder paint, designed based on the latest European standard.
- Design of each tower's volume is based on optimum air movement through the surface and the minimum pressure drop (Maximum 0.21)
- Compact package & non influence to avoid desiccant movement & pollution.
- Compressed air movement through desiccant is from down to up.(Air inlet is in bottom of each column & the outlet is on the top).To keep heavy particles & water drops in the bottom of column & their exit to the outside at regeneration time.
DESICCANT MATERIAL SPESIFICATIONS
The HDT series dryers uses molecular sieve to absorb the humidity.
These materials have maximum quality with below special specifications:
- They are resistant to high temperature & are not damaged or affected in humid, condition.
- They are suitable for dew points up to -70' C
- Its surface resistance is higher than other materials & have minimum surface scrape compared to the other kind of absorbents (This will cause the long life of the dust filter element).
- Maximum operating time is between 3-5 years if they are correctly used.
Dryer Performances
Weight (kg) |
Dimension (mm) |
CONNECTIONS
SIZE |
INLET AIR db |
MODEL |
C |
B |
A |
[scfm] |
[Nm3/h] |
[NI/min] |
55 |
1.145 |
400 |
445 |
G 3/8" BSP-F |
11 |
19.2 |
320 |
HDT 3 |
65 |
1.735 |
400 |
445 |
G 3/8" BSP-F |
19 |
31.8 |
530 |
HDT 5 |
71 |
1.830 |
400 |
450 |
G 3/8" BSP-F |
27 |
45.6 |
760 |
HDT 8 |
87 |
1.945 |
600 |
520 |
G 1/2" BSP-F |
42 |
72 |
1.200 |
HDT 12 |
111 |
1.940 |
600 |
630 |
G 3/4" BSP-F |
65 |
111 |
1.850 |
HDT 18 |
128 |
1.945 |
600 |
755 |
G 1" BSP-F |
88 |
150 |
2.500 |
HDT 25 |
161 |
1.935 |
700 |
885 |
G 1" BSP-F |
106 |
180 |
3.000 |
HDT 30 |
186 |
1.920 |
700 |
920 |
G 1.1/2" BSP-F |
138 |
234 |
3.900 |
HDT 40 |
232 |
1.985 |
700 |
1.005 |
G 1.1/2" BSP-F |
177 |
300 |
5.000 |
HDT 50 |
283 |
1.940 |
700 |
1.035 |
G 1.1/2" BSP-F |
219 |
372 |
6.200 |
HDT 60 |
305 |
2.000 |
700 |
1.060 |
G 1.1/2" BSP-F |
265 |
450 |
7.500 |
HDT 75 |
340 |
1.995 |
700 |
1.060 |
G 1.1/2" BSP-F |
318 |
540 |
9.000 |
HDT 90 |
403 |
2.020 |
760 |
1.200 |
G 2" BSP-F |
452 |
768 |
12.800 |
HDT 130 |
485 |
2.020 |
870 |
1.310 |
G 2" BSP-F |
572 |
972 |
16.200 |
HDT 160 |
702 |
2.165 |
1.040 |
1.475 |
G 2.1/2" BSP-F |
724 |
1.230 |
20.500 |
HDT 200 |
813 |
2.180 |
1.050 |
1.525 |
G 2.1/2" BSP-F |
901 |
1.530 |
25.500 |
HDT 250 |
1.113 |
2.280 |
1.050 |
1.535 |
DN 80-PN 16 |
1.060 |
1.800 |
30.000 |
HDT 300 |
1.250 |
2.320 |
1.200 |
1.625 |
DN 80-PN 16 |
1.272 |
2.160 |
36.000 |
HDT 350 |
1.850 |
2.340 |
1.200 |
1.675 |
DN 80-PN 16 |
1.484 |
2.520 |
42.000 |
HDT 400 |
2.400 |
2.465 |
1.300 |
1.800 |
DN 100-PN 16 |
1.611 |
2.736 |
45.600 |
HDT 450 |
2.800 |
2.485 |
1.600 |
1.985 |
DN 125-PN 16 |
2.208 |
3.750 |
62.500 |
HDT 620 |
3.400 |
2.680 |
1.760 |
2.260 |
DN 150-PN 16 |
2.862 |
4.860 |
81.000 |
HDT 800 |
4.000 |
2.700 |
1.940 |
2.480 |
DN 150-PN 16 |
3.604 |
6.120 |
102.000 |
HDT 1000 |
4.900 |
2.885 |
2.210 |
2.640 |
DN 150-PN 16 |
4.452 |
7.560 |
126.000 |
HDT 1200 |
5.500 |
2.965 |
2.290 |
2.795 |
DN 200-PN 16 |
5.336 |
9.060 |
151.000 |
HDT 1500 |
|
|
|
|
|
|
|
|
|